{"metadata":{"generator":"Captivate","generatorVersion":"11.8.0","schemaVersion":"","author":"author","title":"","description":"project description","email":"author@company.com","website":"www.company.com","tags":"","thumbnail":"","source":"assets","durationInFrames":990,"frameRate":30,"totalSlides":11,"width":1000,"height":562,"responsive":false,"scalable":false,"launchFile":"index_scorm.html","isVRProject":false},"contentStructure":[{"id":"Do_Not_Delete_Hides_Menu","class":"TODO::Senthil","instance":"Do_Not_Delete_Hides_Menu","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"SVG_1","class":"TODO::Senthil","instance":"SVG_1","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_3","class":"TODO::Senthil","instance":"Text_Caption_3","title":"Suctioning ","roles":{"textData":{}}},{"id":"Line_1","class":"TODO::Senthil","instance":"Line_1","roles":{}},{"id":"Image_54","class":"TODO::Senthil","instance":"Image_54","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Page_Counter","class":"TODO::Senthil","instance":"Page_Counter","title":"$$cpInfoCurrentSlide$$ of $$TS$$ ","roles":{"textData":{}}},{"id":"SVG_5","class":"TODO::Senthil","instance":"SVG_5","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Next_Button_5","class":"TODO::Senthil","instance":"Next_Button_5","title":" ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"SVG_7","class":"TODO::Senthil","instance":"SVG_7","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Back_Button_7","class":"TODO::Senthil","instance":"Back_Button_7","title":" ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"SmartShape_4","class":"TODO::Senthil","instance":"SmartShape_4","title":"Start ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"si5839","class":"TODO::Senthil","title":"Start ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"si5851","class":"TODO::Senthil","title":"Start ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Image_55","class":"TODO::Senthil","instance":"Image_55","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Slide5562","class":"Normal Slide","instance":"Title Page","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","SVG_1","Text_Caption_3","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","SmartShape_4","si5839","si5851","Image_55"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide5562"}}},{"id":"Image_61","class":"TODO::Senthil","instance":"Image_61","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_316","class":"TODO::Senthil","instance":"Text_Caption_316","title":"Clearing the airway and suctioning ","roles":{"textData":{}}},{"id":"Text_Caption_317","class":"TODO::Senthil","instance":"Text_Caption_317","title":"Seriously ill patients have a weakened ability to spontaneously clear secretions. The appropriate suctioning of soiled airways decreases the risk of aspiration, promotes optimal gas exchange & prevents nosocomial pneumonia. Any physical or mechanical obstructions must be removed if they are occluding the airway. Removing such things as blood, vomitus, secretions, or small food particles will prevent the liquid substance proceeding further down the airway and possibly into the lungs. ","roles":{"textData":{}}},{"id":"Image_68","class":"TODO::Senthil","instance":"Image_68","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_330","class":"TODO::Senthil","instance":"Text_Caption_330","title":"Fingers for solids ","roles":{"textData":{}}},{"id":"Text_Caption_331","class":"TODO::Senthil","instance":"Text_Caption_331","title":"Sunction for liquids ","roles":{"textData":{}}},{"id":"Slide32254","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Image_61","Text_Caption_316","Text_Caption_317","Image_68","Text_Caption_330","Text_Caption_331"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide32254"}}},{"id":"Image_57","class":"TODO::Senthil","instance":"Image_57","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_308","class":"TODO::Senthil","instance":"Text_Caption_308","title":"Types of suctioning units ","roles":{"textData":{}}},{"id":"Text_Caption_309","class":"TODO::Senthil","instance":"Text_Caption_309","title":"Oxygen powered devices (Oxygen-powered devices function only as long as a source of oxygen is available. Once the oxygen source has run out, the vacuum is lost and suction becomes ineffective). Portable hand operated (Hand-powered suction devices do not require any energy source other than an health care provider to create the vacuum. Therefore, these devices lack some typical problems associated with electric- or oxygen-powered devices. Also, hand-powered units can more effectively suction heavier substances, such as thick vomitus). Portable battery operated (Electric suction devices must have fully charged batteries to function effectively. A low battery charge will reduce the effective vacuum and the length of time the unit can be used. Some units allow for constant charging so that the batteries are always fully charged when needed). ","roles":{"textData":{}}},{"id":"Image_69","class":"TODO::Senthil","instance":"Image_69","roles":{"click":{"subtype":"button"},"question":{"quizId":-1,"text":"Image ","type":"graded","interactionType":"choice","score":{"weight":1,"penalty":0}},"textData":{}}},{"id":"Slide31968","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Image_57","Text_Caption_308","Text_Caption_309","Image_69"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide31968"}}},{"id":"Image_63","class":"TODO::Senthil","instance":"Image_63","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_320","class":"TODO::Senthil","instance":"Text_Caption_320","title":"Suctioning catheters ","roles":{"textData":{}}},{"id":"Text_Caption_321","class":"TODO::Senthil","instance":"Text_Caption_321","title":"Suction catheters are used with suctioning devices to clear the airway. They are disposable items. There are usually three (3) suction adjuncts available for use: Y suction catheter (size 6, 8, 12 & 16 FG) Yankauer catheter (single size only) Meconium aspirator (single size only) ","roles":{"textData":{}}},{"id":"Image_70","class":"TODO::Senthil","instance":"Image_70","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Image_71","class":"TODO::Senthil","instance":"Image_71","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_332","class":"TODO::Senthil","instance":"Text_Caption_332","title":"Yankauer catheter ","roles":{"textData":{}}},{"id":"Text_Caption_333","class":"TODO::Senthil","instance":"Text_Caption_333","title":"Meconium aspirator ","roles":{"textData":{}}},{"id":"Text_Caption_334","class":"TODO::Senthil","instance":"Text_Caption_334","title":"Y suction catheter ","roles":{"textData":{}}},{"id":"Slide32370","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Image_63","Text_Caption_320","Text_Caption_321","Image_70","Image_71","Text_Caption_332","Text_Caption_333","Text_Caption_334"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide32370"}}},{"id":"Image_72","class":"TODO::Senthil","instance":"Image_72","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_335","class":"TODO::Senthil","instance":"Text_Caption_335","title":"Yankauer catheter ","roles":{"textData":{}}},{"id":"Text_Caption_336","class":"TODO::Senthil","instance":"Text_Caption_336","title":"This type of catheter is a rigid plastic tube catheter with a large suction tip surrounded by a bulbous head. They are commonly referred to as a \"tonsil tip\" or Yankauer or \"tonsil sucker.\" It is only used to remove secretions from the mouth and oropharynx of an unresponsive client. It is more effective for particulate matter than a soft catheter. ","roles":{"textData":{}}},{"id":"Slide36161","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Image_72","Text_Caption_335","Text_Caption_336"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide36161"}}},{"id":"Text_Caption_340","class":"TODO::Senthil","instance":"Text_Caption_340","title":"Y suction catheter ","roles":{"textData":{}}},{"id":"Text_Caption_341","class":"TODO::Senthil","instance":"Text_Caption_341","title":"These soft suction catheters consists of flexible tubing and are also called a \"French\" catheter. They are typically used for suctioning endotracheal tubes. Additionally, they are suitable for the suctioning of the patient's nares, nasopharynx, oropharynx, stoma, tracheostomy and airway adjuncts. It is used in suctioning in other situations where the rigid catheter cannot be used. ","roles":{"textData":{}}},{"id":"Image_76","class":"TODO::Senthil","instance":"Image_76","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Slide36255","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Text_Caption_340","Text_Caption_341","Image_76"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide36255"}}},{"id":"Image_78","class":"TODO::Senthil","instance":"Image_78","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Text_Caption_345","class":"TODO::Senthil","instance":"Text_Caption_345","title":"Suctioning ","roles":{"textData":{}}},{"id":"Text_Caption_346","class":"TODO::Senthil","instance":"Text_Caption_346","title":"Indications The removal of airway secretions / debris that are unable be spontaneously cleared . Contraindications Nil Complications Hypoxia Airway trauma Stimulate coughing or gagging Vagal stimulation ","roles":{"textData":{}}},{"id":"Slide36349","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Image_78","Text_Caption_345","Text_Caption_346"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide36349"}}},{"id":"Text_Caption_350","class":"TODO::Senthil","instance":"Text_Caption_350","title":"Suctioning procedure ","roles":{"textData":{}}},{"id":"Text_Caption_351","class":"TODO::Senthil","instance":"Text_Caption_351","title":"If appropriate, ensure patient is pre-oxygenated prior to procedure. Select appropriate suction catheter. Use a rigid catheter when suctioning the mouth or oropharynx. If the nasal passages need to be suctioned, select a soft catheter and use low to medium suction (80 to 120 mmHg). A bulb syringe may be used if a soft catheter is not available. Ensure catheter is connected to suction tubing and suction tubing is connected to an appropriate suction device. Test for adequate suction by occluding the catheter's side port. Position yourself at the patient's head. If this is not possible, take a position in which you can observe the airway. Turn on the suction unit. Open airway. Under direct vision gently insert the catheter without occluding the side port. (Yankauer - Place the rigid tip so that the convex (bulging) side is against the roof of the mouth. Insert it no farther down than the base of the tongue). Occlude the catheter's side port to commence suctioning whilst gradually withdrawing the catheter – suctioning should be limited to ≤ 10 second episodes. If necessary, rinse the catheter with water to prevent obstruction of the tubing from dried or thick material. Do this by keeping a bottle of water available and applying suction to the water as necessary to clear the tubing. ","roles":{"textData":{}}},{"id":"Slide36407","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Text_Caption_350","Text_Caption_351"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide36407"}}},{"id":"Text_Caption_352","class":"TODO::Senthil","instance":"Text_Caption_352","title":"Suctioning - specific insertion techniques ","roles":{"textData":{}}},{"id":"Text_Caption_353","class":"TODO::Senthil","instance":"Text_Caption_353","title":"Nasopharyngeal – gently insert the catheter on a downward slant through one nostril along the floor of the nasal cavity to enter the nasopharynx. Tracheostomy – gently insert the catheter into the tracheal tube to the appropriate depth. Airway stoma – gently insert the catheter into the stoma opening until resistance is felt. ","roles":{"textData":{}}},{"id":"Image_82","class":"TODO::Senthil","instance":"Image_82","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Image_83","class":"TODO::Senthil","instance":"Image_83","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Slide36449","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Text_Caption_352","Text_Caption_353","Image_82","Image_83"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide36449"}}},{"id":"Text_Caption_326","class":"TODO::Senthil","instance":"Text_Caption_326","title":"Summary ","roles":{"textData":{}}},{"id":"Text_Caption_327","class":"TODO::Senthil","instance":"Text_Caption_327","title":"Seriously ill patients have a weakened ability to spontaneously clear secretions. Suctioning is a way the To clear a casualty’s airway. ","roles":{"textData":{}}},{"id":"Image_66","class":"TODO::Senthil","instance":"Image_66","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Slide32630","class":"Normal Slide","instance":"Text and Image II","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","Text_Caption_326","Text_Caption_327","Image_66"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide32630"}}},{"id":"svg_background_Title_Page_2","class":"TODO::Senthil","instance":"svg_background_Title_Page_2","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Title_328","class":"TODO::Senthil","instance":"Title_328","title":"Well done! ","roles":{"textData":{}}},{"id":"Text_Caption_329","class":"TODO::Senthil","instance":"Text_Caption_329","title":"Congratulations on completing your course! Click the Leave button to exit or Retry to retake the course. ","roles":{"textData":{}}},{"id":"Start_Button_387","class":"TODO::Senthil","instance":"Start_Button_387","title":"Retry ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"si35856","class":"TODO::Senthil","title":"Retry ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"si35867","class":"TODO::Senthil","title":"Retry ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Start_Button_388","class":"TODO::Senthil","instance":"Start_Button_388","title":"Leave ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"si35895","class":"TODO::Senthil","title":"Leave ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"si35906","class":"TODO::Senthil","title":"Leave ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"SmartShape_389","class":"TODO::Senthil","instance":"SmartShape_389","title":" ","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Image_67","class":"TODO::Senthil","instance":"Image_67","roles":{"click":{"subtype":"button"},"textData":{}}},{"id":"Slide35965","class":"Normal Slide","instance":"Well done","thumbnail":"","children":["Do_Not_Delete_Hides_Menu","Image_54","Page_Counter","SVG_5","Next_Button_5","SVG_7","Back_Button_7","svg_background_Title_Page_2","Title_328","Text_Caption_329","Start_Button_387","si35856","si35867","Start_Button_388","si35895","si35906","SmartShape_389","Image_67"],"roles":{"slide":{"durationInFrames":90},"navigation":{"navid":"Slide35965"}}},{"id":"Pool423","class":"pool","roles":{"pool":{"id":423,"name":"Pool1","questions":[]}}},{"id":"suction","class":"project","title":"suction","children":["Slide5562","Slide32254","Slide31968","Slide32370","Slide36161","Slide36255","Slide36349","Slide36407","Slide36449","Slide32630","Slide35965"],"roles":{"quiz":{"id":379,"branched":false,"submitAll":false,"review":true,"questions":[],"minScore":0,"maxScore":0,"passScore":0}}}],"contentSettings":{"global":{"branchAware":false},"toc":{"navigationEnabled":true,"navigateVisitedSlides":false,"collapseAll":false,"showTopicDuration":false,"statusFlag":true,"selfPaced":false,"showSearch":false,"enabled":true},"playbar":{"enabled":false,"cc":false,"playPause":true,"back":true,"forward":true,"rewind":true,"close":true,"mute":true,"progressBar":true}},"contentReporting":{"CCCriteria":"view","CCData":{"viewDataIsPercent":true,"viewData":100},"SCCriteria":"view","SCData":{"viewDataIsPercent":true,"viewData":100},"exitNormalIfCompleted":false},"toc":[{"id":"Slide31968","title":"Text and Image II","visible":false},{"id":"Slide32630","title":"Text and Image II","visible":false},{"id":"Slide35965","title":"Well done","visible":false},{"id":"Slide32370","title":"Text and Image II","visible":false},{"id":"Slide36161","title":"Text and Image II","visible":false},{"id":"Slide36255","title":"Text and Image II","visible":false},{"id":"Slide36349","title":"Text and Image II","visible":false},{"id":"Slide36407","title":"Text and Image II","visible":false},{"id":"Slide36449","title":"Text and Image II","visible":false},{"id":"Slide32254","title":"Text and Image II","visible":false},{"id":"Slide5562","title":"Title Page","visible":true}]}